MAIN FEATURES
Wilo PressureControl model 2008180 designed for automatic management of self-priming pumps and domestic water boosting systems without a separate expansion vessel.
Automatically starts and stops the pump based on pressure and flow, providing dry-run protection and ensuring system reliability.
TECHNICAL DATA
Single-phase power supply 220 to 250 V, 50–60 Hz
Maximum nominal current 10 A
Start pressure adjustable from 1.5 to 2.7 bar
Maximum operating pressure 10 bar
Maximum flow rate 10 m³/h
Maximum fluid temperature 60°C
Protection rating IP65
Hydraulic connection G1
Compatible with pumps with a minimum shut-off pressure of 2.2 bar
OPERATION
The pressure control automatically starts the pump when pressure drops to the set value and stops it when flow ceases.
Integrated dry-run protection and loss-of-water safety.
APPLICATIONS
Suitable for domestic water boosting systems, wells, autoclaves and small civil water installations.
Compatible with Wilo pumps and Salmonson Acson series as a direct replacement.