MAXIFLAME MODULE FOR THERMO FIREPLACE INTERFACE BOILER THERMO PRODUCT MX135 / 1 SLX
CONNECTIONS 3/4 ", kW 30-35, PLATES 34, PARA PUMP 15/6
Through the module it is possible to carry out the heating function of the housing unit by exploiting the heat produced both by the solid fuel boiler (open or closed vessel) and by the gas boiler, hydraulically separating the two circuits by means of a plate exchanger, for avoid adding the powers of the two generators as required by INAIL (formerly ISPESL) standards. The module is equipped with one or two circulators, an exchanger, two air vent valves, a non-return valve, and wall mounting kit, integrated control unit and shut-off cocks.
The cover BOX can also be installed recessed.